Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Chinese Journal of Tissue Engineering Research ; (53): 5789-5792, 2009.
Article in Chinese | WPRIM | ID: wpr-406098

ABSTRACT

BACKGROUND:At present,syndromes happening frequency of diabetes mellitus can be controlled through regulating glucose concentration in blood.Therefore,a fast,steady,accurate glucose biosensor has been an intense area of focus for investigators.OBJECTIVE:To observe the effect of chitosan-gold nanoparticles hybrid film on electrochemical glucose biosensor.DESIGN,TIME AND SETTING:The observation experiment was performed at the Department of Medicine Laboratory,General Hospital,Guangzhou Military Command of Chinese PLA from February to April 2009.MATERIALS:Based on the immobilization of glucose oxidase (GOD) with cross-linking in the matrix of chitosan on an Au electrode by glutaraldehyde,a novel glucose biosensor was constructed with gold nanoparticles by electrodeposition.METHODS:The properties of CHIT/AuNPs hybrid film modified electrode were characterized by cyclic voltammetry (CV) in 20 mmol/L K3Fe (CN)6-0.1 mol/L KCI system by using the three-electrode system and the response to glucose was investigated by linear scan voltammetry (LSV).The optimal experiment conditions,stability and reproducibility about the glucose biosensor were also studied.MAIN OUTCOME MEASURES:The cyclic voltammetry properties of different modified electrode,as well as relation between glucose concentration and response current.RESULTS:Glucose concentration showed a linear correlation with response current in range of 0.001-6 mmol/L.The biosensor exhibited excellent performances of producibility,stability and the ignorance interferences of reducing substances,with the CONCLUSION:The glucose biosensor possesses excellent reproducibility and stability with a fast response time to glucose,which can be used in detection of glucose concentration in human serum.

2.
Chinese Medical Equipment Journal ; (6)1989.
Article in Chinese | WPRIM | ID: wpr-594379

ABSTRACT

Objective To construct a kind of novel electrochemical glucose biosensor for clinical detection.Methods Multiwall carbon tube(MWCNTs),NanoAu and glucose oxidase(GOD) were immobilized on the Au electrode by monolayer self-assemble.Cyclic voltammetry and linear scan voltammetry were used to investigate the assembling process and the chemical characteristics of the glucose biosensor.Results The linearity of glucose in the range of 10~1 400 mg/L with the correlation coefficient of R2=0.990 9 was obtained by linear scan voltammetry and the detection limited reached 0.000 1 mg/L.The four criterion samples were measured with 3 different biosensors in same conditions and the RSD

SELECTION OF CITATIONS
SEARCH DETAIL